VIEW900

The Most Reliable & Accurate Cable Antenna Analyzer

VIEW900

VIEW900 is equipment that analyze antenna and cable errors. It is used for maintenance of a wireless signaling outgoing system by antenna. It can confirm issues in both antenna and linking cables between antenna and system. ‘Return Loss’ and ‘VSWR’ are able to measure antenna.

In addtion, ‘DTF Return Loss’, ‘DTF VSWR’ and ‘Cable Loss’ are functions for measuring cable. VIEW900 is available 5MHz ~ 6GHz and ‘Trace point’ can sets up upto 2049 points. Full touched 7 inch wide LCD and 7800mA Li-ion detachable battery will enable the user to operate esaily.

Lastly, VIEW900 can be calibrated by ‘Mechanical Calibration Kit(V96)’ and ‘Electrical Calibration Kit(V95).

Download for SW and marketing material

Catalog

Manual

Software

the Most Reliable & Accurate Cable Antenna Analyzer

Serves to installation and maintenance of cell sites

Measure brilliantly with VIEW900

Clear visibility for
working environment

The Optimized 7 inch high-resolution Color LCD Touch Screen

The Highest Resolution of 800 x 480

Easy-To-Operate, Intuituve GUI

DIMENSION

188H x 272W x 65D mm
(excluding rubber bumper)

WEIGHT

2.1KG (with battery)

DISPLAY

High Brightness TFT LCD /
Resolution of 800×480

RETURN LOSS / VSWR

Return Loss Range : 0 ~ 60dB
VSWR Range : 1 to 65

DTF

Return Loss Display Range : 0 to 60 dB
VSWR Display Range : 0 to 65
Distance : 0 to 1250m(4125ft)

CABLE LOSS

Cable Loss Range : 0 to 30dB

Item Sub Item Specification
General Max input power +25 dBm ( +33 dBm damage level)
Frequency Range 5 MHz to 6 GHz
Frequency Accuracy <±3ppm
Frequency Resolution 10 kHz
Scan Speed Reflection: < 0.7 ms/point
DTF: < 1.0 ms/point
Number of Data Points 129, 257, 513, 1025, 2049
Display Single & Dual display
Test Port N-Type Female, 50 Ω
Storage (Trace / Screen / Setup) Internal: Minimum 512 MB
External: Limited by size of USB (32 G)
Interference Immunity On Frequency +5 dBm
On Channel +15 dBm
Miscellaneous Voltage and Current 12 VDC, 3.0 A
Adaptor AC Input
DC Output
100 to 240 V, 1.5 A
12 VDC, 3.0 A
Battery Li-ion 7800 mAh
(5.5 hr operating time after full charge)
Environmental Operating Temperature -10 °C ~ +50 °C
(14 °F ~ +122 °F)
Storage Temperature -40 °C ~ +80 °C
(-40 °F ~ +176 °F
Humidity 95 % R.H. No Condensation
Package
Cable Antenna Analyzer VIEW 900
Power cable / AC Adapter ACC-25 / INNO-PU-8
Battery LBT-230A
Carrying case Soft case / Hard case(Option)
Shoulder strap
USB 8G
V90(Optional Accessories)
Frequency range 50MHz to 6000MHz
Output Power range -45dBm to + 10dBm
Min/Max input power range -50dBm / +15dBm
Measurement Type Average
Measurement Uncertainty ±7%
S11(return loss) Below -25dBm
Dimensions LxWxH 137x53x36mm
Weight less than 296g
V95(Optional Accessories)
Frequency range 5MHz to 6000MHz
DC voltage 5V/500mA (With USB cable)
Power consumption 5V 0.06A (0.3W)
Dimensions LxWxH 113x38x27 mm
Weight Less than 162g
Operating temperature 0 °C to 50 °C

VSWR

VSWR(voltage standing wave ratio) measures effective transmission of the energy sent to antenna by comparing an incident wave of antenna and a reflected wave.

RETURN LOSS

Return Loss is the ratio of power loss between incident and reflected power in mismatching of antenna and RF cable(displayed in log scale.)

DISTANCE TO FAULT

Distance to Fault can detect defectlocation of disconnection and damaged of RF cable.

CABLE LOSS

Cable Loss is for reflection loss measurement of RF cable (displayed in log scale).

SMITH CHART

Smith Chart is an RF tool to make sure impedance matching status by measuring an impedance of transmission system includes antenna and RF cables.

POWER MEASUREMENT

RF power measurement using an external power sensor.

Let’s Stay Connected!